Description
(Infrared Microscope)
Perform Infrared Measurements Smoothly While Viewing Visible Images
– Visible/Infrared Dual View System –
Finally, a wide view on micro sample analysis. Infrared spectra can be measured while checking a visible image of the sample. Spectra can be measured while confirming the position of contaminants, which avoids the trouble of switching back and forth between the visible light and infrared light. Used in combination with the tiling function, visible observations and infrared measurements can be performed anywhere within the stage operating range, eliminating the need to reposition the sample.
This therapy is commonly used for the palliative treatment of pain and swelling (both post-operative and regular), among other things, and as a very effective tool that will help wounds heal.
With its low-power settings, this device is exceptionally well suited to the treatment of acute conditions. Recent large-scale research has shown that this method is particularly well suited to the relief of post-operative pain and the promotion of post-operative wound healing
A Series of Smooth Micro Analysis
Load Sample
- Loading Samples Is Easy.
Pressing the [Eject Sample] button makes it easy to load and remove samples by automatically lowering the stage and switching the objectives to expand space. Furthermore, the lower Condenser mirror can be removed to enable reflectance/ATR measurements of samples up to 40 mm thick.
Look for the Item to Be Measured
- Quickly Determine the Measurement Position -Wide-Field Camera* and Microscope Camera –
Shimadzu’s proprietary wide-field camera and microscope camera help observe samples efficiently. In addition to observing a large area up to 10 × 13 mm, the wide-field camera also supports variable digital zooming. Furthermore, by sharing positional information with the microscope camera, it achieves a digital zoom function capable of zooming to a magnification of about 330× for observing areas as small as 30 × 40 µm. (The microscope camera supports variable digital zoom magnifications up to 10×.)
Determine Where to Measure, and Measure Automatically
- Automatically Determine Measurement Positions -Automatic Contaminant Recognition System –
A function that automatically recognizes contaminants is included standard. The analyst simply clicks one button and the software automatically recognizes the contaminant. It even determines the optimal aperture size and angle instantaneously.
Two modes are available: the standard mode and one optimized for extremely small areas. Users can choose the best model for their application. The automatically determined measurement positions can either be measured without editing or the analyst can add or delete measurement positions. Sample images are stored into the measured spectra automatically. The sample and measurement positions can be easily identified later.
Identify the Cause of Failures
- Automatic Identification of Contaminants -Contaminant Analysis Program –
The contaminant analysis program – the functionality for automatically qualifying contaminants – is included as a standard feature in LabSolutions™ IR software. Measured spectra using AIMsolution can be loaded directly into LabSolutions IR and analyzed.
The contaminant analysis program identifies measured contaminants with high precision using a spectral library for substances commonly detected as contaminants in combination with Shimadzu’s proprietary identification algorithm (patent pending).